Advertisement
desdemona

smartctl -a /dev/sda

Jun 1st, 2015
493
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
  1. smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-23-generic] (local build)
  2. Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family:     Western Digital Scorpio Blue Serial ATA (Adv. Format)
  6. Device Model:     WDC WD5000BPVT-22HXZT1
  7. Serial Number:    WD-WX31A41Y1950
  8. LU WWN Device Id: 5 0014ee 65678a5b1
  9. Firmware Version: 01.01A01
  10. User Capacity:    500,107,862,016 bytes [500 GB]
  11. Sector Sizes:     512 bytes logical, 4096 bytes physical
  12. Device is:        In smartctl database [for details use: -P show]
  13. ATA Version is:   8
  14. ATA Standard is:  Exact ATA specification draft version not indicated
  15. Local Time is:    Mon Jun  1 22:10:48 2015 UTC
  16. SMART support is: Available - device has SMART capability.
  17. SMART support is: Enabled
  18.  
  19. === START OF READ SMART DATA SECTION ===
  20. SMART overall-health self-assessment test result: PASSED
  21.  
  22. General SMART Values:
  23. Offline data collection status:  (0x00) Offline data collection activity
  24.                     was never started.
  25.                     Auto Offline Data Collection: Disabled.
  26. Self-test execution status:      (   0) The previous self-test routine completed
  27.                     without error or no self-test has ever
  28.                     been run.
  29. Total time to complete Offline
  30. data collection:        (11760) seconds.
  31. Offline data collection
  32. capabilities:            (0x7b) SMART execute Offline immediate.
  33.                     Auto Offline data collection on/off support.
  34.                     Suspend Offline collection upon new
  35.                     command.
  36.                     Offline surface scan supported.
  37.                     Self-test supported.
  38.                     Conveyance Self-test supported.
  39.                     Selective Self-test supported.
  40. SMART capabilities:            (0x0003) Saves SMART data before entering
  41.                     power-saving mode.
  42.                     Supports SMART auto save timer.
  43. Error logging capability:        (0x01) Error logging supported.
  44.                     General Purpose Logging supported.
  45. Short self-test routine
  46. recommended polling time:    (   2) minutes.
  47. Extended self-test routine
  48. recommended polling time:    ( 117) minutes.
  49. Conveyance self-test routine
  50. recommended polling time:    (   5) minutes.
  51. SCT capabilities:          (0x7035) SCT Status supported.
  52.                     SCT Feature Control supported.
  53.                     SCT Data Table supported.
  54.  
  55. SMART Attributes Data Structure revision number: 16
  56. Vendor Specific SMART Attributes with Thresholds:
  57. ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  58.  1 Raw_Read_Error_Rate     0x002f   199   199   051    Pre-fail  Always       -       21835
  59.  3 Spin_Up_Time            0x0027   205   153   021    Pre-fail  Always       -       708
  60.  4 Start_Stop_Count        0x0032   093   093   000    Old_age   Always       -       7826
  61.  5 Reallocated_Sector_Ct   0x0033   193   193   140    Pre-fail  Always       -       66
  62.  7 Seek_Error_Rate         0x002e   200   200   000    Old_age   Always       -       0
  63.  9 Power_On_Hours          0x0032   086   086   000    Old_age   Always       -       10294
  64. 10 Spin_Retry_Count        0x0032   100   100   000    Old_age   Always       -       0
  65. 11 Calibration_Retry_Count 0x0032   100   100   000    Old_age   Always       -       0
  66. 12 Power_Cycle_Count       0x0032   097   097   000    Old_age   Always       -       3441
  67. 191 G-Sense_Error_Rate      0x0032   001   001   000    Old_age   Always       -       4328
  68. 192 Power-Off_Retract_Count 0x0032   200   200   000    Old_age   Always       -       43
  69. 193 Load_Cycle_Count        0x0032   142   142   000    Old_age   Always       -       175605
  70. 194 Temperature_Celsius     0x0022   111   096   000    Old_age   Always       -       36
  71. 196 Reallocated_Event_Count 0x0032   197   197   000    Old_age   Always       -       3
  72. 197 Current_Pending_Sector  0x0032   200   001   000    Old_age   Always       -       50
  73. 198 Offline_Uncorrectable   0x0030   100   253   000    Old_age   Offline      -       0
  74. 199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       -       0
  75. 200 Multi_Zone_Error_Rate   0x0008   100   253   000    Old_age   Offline      -       0
  76.  
  77. SMART Error Log Version: 1
  78. No Errors Logged
  79.  
  80. SMART Self-test log structure revision number 1
  81. No self-tests have been logged.  [To run self-tests, use: smartctl -t]
  82.  
  83.  
  84. SMART Selective self-test log data structure revision number 1
  85. SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
  86.    1        0        0  Not_testing
  87.    2        0        0  Not_testing
  88.    3        0        0  Not_testing
  89.    4        0        0  Not_testing
  90.    5        0        0  Not_testing
  91. Selective self-test flags (0x0):
  92.  After scanning selected spans, do NOT read-scan remainder of disk.
  93. If Selective self-test is pending on power-up, resume after 0 minute delay.