  1. root@diavita-newprod:~# smartctl -a /dev/sda
  2. smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.16.0-4-amd64] (local build)
  3. Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
  4.  
  5. === START OF INFORMATION SECTION ===
  6. Device Model: WDC WD2004FBYZ-01YCBB1
  7. Serial Number: WD-WMC6N0E5DH76
  8. LU WWN Device Id: 5 0014ee 0599a639b
  9. Firmware Version: RR04
  10. User Capacity: 2,000,398,934,016 bytes [2.00 TB]
  11. Sector Size: 512 bytes logical/physical
  12. Rotation Rate: 7200 rpm
  13. Form Factor: 3.5 inches
  14. Device is: Not in smartctl database [for details use: -P showall]
  15. ATA Version is: ACS-3 T13/2161-D revision 5
  16. SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
  17. Local Time is: Mon Nov 19 09:26:26 2018 CET
  18. SMART support is: Available - device has SMART capability.
  19. SMART support is: Enabled
  20.  
  21. === START OF READ SMART DATA SECTION ===
  22. SMART overall-health self-assessment test result: PASSED
  23.  
  24. General SMART Values:
  25. Offline data collection status: (0x00) Offline data collection activity
  26. was never started.
  27. Auto Offline Data Collection: Disabled.
  28. Self-test execution status: ( 0) The previous self-test routine completed
  29. without error or no self-test has ever
  30. been run.
  31. Total time to complete Offline
  32. data collection: ( 0) seconds.
  33. Offline data collection
  34. capabilities: (0x7b) SMART execute Offline immediate.
  35. Auto Offline data collection on/off support.
  36. Suspend Offline collection upon new
  37. command.
  38. Offline surface scan supported.
  39. Self-test supported.
  40. Conveyance Self-test supported.
  41. Selective Self-test supported.
  42. SMART capabilities: (0x0003) Saves SMART data before entering
  43. power-saving mode.
  44. Supports SMART auto save timer.
  45. Error logging capability: (0x01) Error logging supported.
  46. General Purpose Logging supported.
  47. Short self-test routine
  48. recommended polling time: ( 2) minutes.
  49. Extended self-test routine
  50. recommended polling time: ( 214) minutes.
  51. Conveyance self-test routine
  52. recommended polling time: ( 5) minutes.
  53. SCT capabilities: (0x003d) SCT Status supported.
  54. SCT Error Recovery Control supported.
  55. SCT Feature Control supported.
  56. SCT Data Table supported.
  57.  
  58. SMART Attributes Data Structure revision number: 16
  59. Vendor Specific SMART Attributes with Thresholds:
  60. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  61. 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
  62. 3 Spin_Up_Time 0x0027 184 183 021 Pre-fail Always - 3791
  63. 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 13
  64. 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
  65. 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
  66. 9 Power_On_Hours 0x0032 083 083 000 Old_age Always - 13000
  67. 10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0
  68. 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0
  69. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 11
  70. 16 Unknown_Attribute 0x0022 004 196 000 Old_age Always - 250108791122
  71. 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
  72. 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 6
  73. 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 1780
  74. 194 Temperature_Celsius 0x0022 110 108 000 Old_age Always - 37
  75. 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
  76. 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
  77. 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0
  78. 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
  79. 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
  80.  
  81. SMART Error Log Version: 1
  82. No Errors Logged
  83.  
  84. SMART Self-test log structure revision number 1
  85. No self-tests have been logged. [To run self-tests, use: smartctl -t]
  86.  
  87. SMART Selective self-test log data structure revision number 1
  88. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  89. 1 0 0 Not_testing
  90. 2 0 0 Not_testing
  91. 3 0 0 Not_testing
  92. 4 0 0 Not_testing
  93. 5 0 0 Not_testing
  94. Selective self-test flags (0x0):
  95. After scanning selected spans, do NOT read-scan remainder of disk.
  96. If Selective self-test is pending on power-up, resume after 0 minute delay.