- Alexandre Jadin <alexandre.jadin@traxxeo.com>
- Wed, Feb 12, 11:53 AM
- to Yordan, me
- Hello Yordan, Petar
- Pavel had issue with the WBS project OVW (Oosterweelverbinding)
- Available with TRAXXEOTEAM account
- Here is what he did:
- Create the WBS LVL0 with ref_number = OVW
- Add LVL 1 WBS(s) to the parent
- Mark the LVL0 as deleted (or obsolete)
- Re-activate the LVL0 WBS
- After correct sync with MFRAME, the project was visible in MFRAME Timesheet (mobile app) but not its underlying structure
- The LVL0 WBS had its flag CAN_ASSIGN_TEAM = ‘N’
- Setting this flag to ‘Y’ solved the problem (did that with SQLDev)
- I deduced that this flag should always be set to Y for a LVL0 active WBS (Jordy wasn’t sure but agreed it makes sense), but somehow, when re-activating the WBS LVL0 , the flag wasn’t changed
- Can you check out the procedure called when re-enabling a WBS and see if it makes sense/is possible to set this flag on this operation?
- Thanks in advance,
- Alexandre