Advertisement
Infra_HDC

for-cyberlink-20190221-001 -- WDC_WD2000FYYZ-01UL1B1_WD-WMC1

Feb 21st, 2019
356
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 4.66 KB | None | 0 0
  1. smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.9.0-8-amd64] (local build)
  2. Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family: Western Digital Re
  6. Device Model: WDC WD2000FYYZ-01UL1B1
  7. Serial Number: WD-WMC1P0235744
  8. LU WWN Device Id: 5 0014ee 25ec59921
  9. Firmware Version: 01.01K02
  10. User Capacity: 2,000,398,934,016 bytes [2.00 TB]
  11. Sector Size: 512 bytes logical/physical
  12. Rotation Rate: 7200 rpm
  13. Device is: In smartctl database [for details use: -P show]
  14. ATA Version is: ATA8-ACS (minor revision not indicated)
  15. SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
  16. Local Time is: Thu Feb 21 11:40:50 2019 MSK
  17. SMART support is: Available - device has SMART capability.
  18. SMART support is: Enabled
  19.  
  20. === START OF READ SMART DATA SECTION ===
  21. SMART overall-health self-assessment test result: PASSED
  22.  
  23. General SMART Values:
  24. Offline data collection status: (0x82) Offline data collection activity
  25. was completed without error.
  26. Auto Offline Data Collection: Enabled.
  27. Self-test execution status: ( 0) The previous self-test routine completed
  28. without error or no self-test has ever
  29. been run.
  30. Total time to complete Offline
  31. data collection: (25980) seconds.
  32. Offline data collection
  33. capabilities: (0x7b) SMART execute Offline immediate.
  34. Auto Offline data collection on/off support.
  35. Suspend Offline collection upon new
  36. command.
  37. Offline surface scan supported.
  38. Self-test supported.
  39. Conveyance Self-test supported.
  40. Selective Self-test supported.
  41. SMART capabilities: (0x0003) Saves SMART data before entering
  42. power-saving mode.
  43. Supports SMART auto save timer.
  44. Error logging capability: (0x01) Error logging supported.
  45. General Purpose Logging supported.
  46. Short self-test routine
  47. recommended polling time: ( 2) minutes.
  48. Extended self-test routine
  49. recommended polling time: ( 284) minutes.
  50. Conveyance self-test routine
  51. recommended polling time: ( 5) minutes.
  52. SCT capabilities: (0x70bd) SCT Status supported.
  53. SCT Error Recovery Control supported.
  54. SCT Feature Control supported.
  55. SCT Data Table supported.
  56.  
  57. SMART Attributes Data Structure revision number: 16
  58. Vendor Specific SMART Attributes with Thresholds:
  59. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  60. 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
  61. 3 Spin_Up_Time 0x0027 173 165 021 Pre-fail Always - 6350
  62. 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 297
  63. 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
  64. 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
  65. 9 Power_On_Hours 0x0032 045 045 000 Old_age Always - 40489
  66. 10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
  67. 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
  68. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 297
  69. 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
  70. 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 48
  71. 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 252
  72. 194 Temperature_Celsius 0x0022 115 106 000 Old_age Always - 35
  73. 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
  74. 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
  75. 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0
  76. 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
  77. 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
  78.  
  79. SMART Error Log Version: 1
  80. No Errors Logged
  81.  
  82. SMART Self-test log structure revision number 1
  83. No self-tests have been logged. [To run self-tests, use: smartctl -t]
  84.  
  85. SMART Selective self-test log data structure revision number 1
  86. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  87. 1 0 0 Not_testing
  88. 2 0 0 Not_testing
  89. 3 0 0 Not_testing
  90. 4 0 0 Not_testing
  91. 5 0 0 Not_testing
  92. Selective self-test flags (0x0):
  93. After scanning selected spans, do NOT read-scan remainder of disk.
  94. If Selective self-test is pending on power-up, resume after 0 minute delay.
Advertisement