- smartctl 6.5 2016-05-07 r4318 [x86_64-linux-4.11.11-300.fc26.x86_64] (local build)
- Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Toshiba 2.5" HDD MQ01ABD...
- Device Model: TOSHIBA MQ01ABD050
- Serial Number: X38APOJOT
- LU WWN Device Id: 5 000039 5126010c0
- Firmware Version: AX001A
- User Capacity: 500,107,862,016 bytes [500 GB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 5400 rpm
- Form Factor: 2.5 inches
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ATA8-ACS (minor revision not indicated)
- SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
- Local Time is: Fri Aug 11 21:03:34 2017 -03
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 120) seconds.
- Offline data collection
- capabilities: (0x5b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 118) minutes.
- SCT capabilities: (0x003d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
- 2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline - 0
- 3 Spin_Up_Time 0x0027 100 100 001 Pre-fail Always - 1032
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 8984
- 5 Reallocated_Sector_Ct 0x0033 100 100 050 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
- 8 Seek_Time_Performance 0x0005 100 100 050 Pre-fail Offline - 0
- 9 Power_On_Hours 0x0032 090 090 000 Old_age Always - 4134
- 10 Spin_Retry_Count 0x0033 253 100 030 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 1319
- 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 2913
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 87
- 193 Load_Cycle_Count 0x0032 096 096 000 Old_age Always - 49959
- 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 33 (Min/Max 14/48)
- 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 161
- 220 Disk_Shift 0x0002 100 100 000 Old_age Always - 0
- 222 Loaded_Hours 0x0032 093 093 000 Old_age Always - 3085
- 223 Load_Retry_Count 0x0032 100 100 000 Old_age Always - 0
- 224 Load_Friction 0x0022 100 100 000 Old_age Always - 0
- 226 Load-in_Time 0x0026 100 100 000 Old_age Always - 271
- 240 Head_Flying_Hours 0x0001 100 100 001 Pre-fail Offline - 0
- SMART Error Log Version: 1
- ATA Error Count: 247 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 247 occurred at disk power-on lifetime: 4108 hours (171 days + 4 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 84 41 f0 f7 62 0c 40 Error: ICRC, ABRT at LBA = 0x000c62f7 = 811767
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 00 f0 f8 61 0c 40 00 00:13:03.801 READ FPDMA QUEUED
- 60 18 e8 e0 5d 0c 40 00 00:13:03.762 READ FPDMA QUEUED
- 60 00 e0 e0 59 0c 40 00 00:13:03.762 READ FPDMA QUEUED
- b0 da 00 00 4f c2 00 00 00:13:03.664 SMART RETURN STATUS
- ea 00 00 00 00 00 a0 00 00:13:03.664 FLUSH CACHE EXT
- Error 246 occurred at disk power-on lifetime: 4108 hours (171 days + 4 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 84 41 f0 e7 fc 0a 40 Error: ICRC, ABRT at LBA = 0x000afce7 = 720103
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 f8 f0 f0 f4 0a 40 00 00:12:59.447 READ FPDMA QUEUED
- ea 00 00 00 00 00 a0 00 00:12:59.447 FLUSH CACHE EXT
- ea 00 00 00 00 00 a0 00 00:12:59.436 FLUSH CACHE EXT
- 61 20 d8 f8 04 0d 40 00 00:12:59.436 WRITE FPDMA QUEUED
- 60 20 d0 70 f4 0a 40 00 00:12:59.435 READ FPDMA QUEUED
- Error 245 occurred at disk power-on lifetime: 4080 hours (170 days + 0 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 84 41 88 df bd 55 40 Error: ICRC, ABRT at LBA = 0x0055bddf = 5619167
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 00 88 e0 bc 55 40 00 00:15:10.376 READ FPDMA QUEUED
- 60 00 80 e0 bb 55 40 00 00:15:10.375 READ FPDMA QUEUED
- 60 00 78 e0 ba 55 40 00 00:15:10.373 READ FPDMA QUEUED
- 60 00 70 e0 b9 55 40 00 00:15:10.372 READ FPDMA QUEUED
- 60 00 68 e0 b8 55 40 00 00:15:10.368 READ FPDMA QUEUED
- Error 244 occurred at disk power-on lifetime: 3992 hours (166 days + 8 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 84 41 88 1f 60 70 40 Error: ICRC, ABRT at LBA = 0x0070601f = 7364639
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 00 88 20 5f 70 40 00 04:41:57.559 READ FPDMA QUEUED
- 60 00 80 20 5e 70 40 00 04:41:57.558 READ FPDMA QUEUED
- 60 00 78 20 5d 70 40 00 04:41:57.557 READ FPDMA QUEUED
- 60 00 70 20 5c 70 40 00 04:41:57.555 READ FPDMA QUEUED
- 60 00 68 20 5b 70 40 00 04:41:57.555 READ FPDMA QUEUED
- Error 243 occurred at disk power-on lifetime: 3898 hours (162 days + 10 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 84 41 e0 ff 59 66 40 Error: ICRC, ABRT at LBA = 0x006659ff = 6707711
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 00 e0 00 59 66 40 00 00:01:35.588 READ FPDMA QUEUED
- 60 00 d8 00 58 66 40 00 00:01:35.587 READ FPDMA QUEUED
- 60 00 d0 00 57 66 40 00 00:01:35.585 READ FPDMA QUEUED
- 60 00 c8 00 56 66 40 00 00:01:35.584 READ FPDMA QUEUED
- 60 00 c0 00 55 66 40 00 00:01:35.577 READ FPDMA QUEUED
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Extended offline Completed without error 00% 4127 -
- # 2 Extended offline Completed without error 00% 4125 -
- # 3 Short offline Completed without error 00% 4122 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.